Filtro de pneumática de qualidade filtro de secador de ar
$53.1810-49 Piece/Pieces
$50.55≥50Piece/Pieces
Tipo de pagamento: | T/T |
Incoterm: | EXW |
transporte: | Ocean,Land,Air,Express |
porta: | Shenzhen,GUANGZHOU,SHANGHAI |
Ms. YUKA Filtration
O que posso fazer por você?
$53.1810-49 Piece/Pieces
$50.55≥50Piece/Pieces
Tipo de pagamento: | T/T |
Incoterm: | EXW |
transporte: | Ocean,Land,Air,Express |
porta: | Shenzhen,GUANGZHOU,SHANGHAI |
Modelo: YD-B058
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Element Serve Life: 6000~8000 Hours
Filtration Performance: From 5 μm To 0.01μm
Maxi. Operate Pressure: 1.6mpa
Operate Temperature: 1.5~80ºc
Flow Rate: 2.8m³/Min
Resistance Corrosion: Inside And Outside
Parts: Dp Indicator, Auto Drain, Sight Glass
Diversion Fin Design On Element Top Cap: Less Pressure Loss
O-Ring Material: Fluororubber
Color: Blue
OEM & ODM Service: Yes
Trademark: Yuka
Transport Package: Brown Inner Box & Cardboard
Specification: Dimension: 120 X 110 X 349mm
Origin: China
Código HS: 8421399090
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Efficiency: F5
Filtration Grade: Medium Filter
Type: Cartridge Filter
Unidades de venda | : | Piece/Pieces |
Tipo de pacote | : | CAIXA DE PAPELÃO |
Exemplo de imagem | : |
The file is encrypted. Please fill in the following information to continue accessing it
O princípio de trabalho do filtro de ar comprimido:
Efeito da gravidade: quando a velocidade do ar no filtro é baixa, a maioria das gotículas de óleo com um diâmetro de 20-50um é coletada por queda livre por gravidade antes de atingir a camada de filtro. Além disso, o fluxo de ar continua a cair e se acumular à medida que flui através do filtro. Quanto maior a velocidade do ar, menor sua eficiência.
Impactação inercial: geralmente, partículas suspensas com um diâmetro maior que 1um têm um grande impulso. Nem sempre é consistente com o caminho do fluxo de ar, por isso atingirá -o de maneira inerta a camada de fibra. Quanto maior a velocidade do ar, maior a taxa de colisão.
Interceptação direta: partículas com um diâmetro de 0,3-1um movendo com o fluxo de ar, e a maioria delas será interceptada e separada pela camada de fibra a 1/2 do elemento de filtro. Quanto menor a partícula, menor a taxa de interceptação.
Penetração: partículas com um diâmetro inferior a 0,3um. Como a massa é pequena demais para ter a versatilidade dos líquidos, eles se movem em um movimento browniano irregular. É inconsistente com o caminho do fluxo de ar e é precisamente por causa desse movimento que pode ser capturado por uma camada de filtro mais fina. Quanto menor as partículas. Quanto mais intenso o movimento browniano, maior a chance de pegá -lo.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe Size | Max Flow rates | Dimension(mm) | |||||||
L/S | m³/min | cfm | W (Width) | D (Diameter) | H (Height) | A | B | C(clearance for housing) | ||
YD-B017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 349 | 55 | 290 | 264 |
YD-B068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 369 | 55 | 310 | 264 |
YD-B080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 892 | 78 | 815 | 762 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |