Modelo: HG068
Element Serve Life: 6000~8000 Hours
Clapboard: Without Clapboard
Medium Material: Fiberglass
Type: Cartridge Filter
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Filtration Performance: From 5 μm To 0.01μm
Operate Temperature: 1.5~80ºc
Transport Package: Brown Inner Box & Cardboard
Filtration Efficiency: 99.99%
Element Material: Sodium Borosilicate Glass Fiber
Maxi. Operate Pressure: 1.0 Mpa
Auto Drain Parts: Anti-Collision Nut
Filtration Grade: Ulpa Filter
Connection: Rc1"
Element Design: Without Tie-Rod
Parallel Design: Available
Sight Glass: Two
Flow Rate: 3.6 M³/Min
Specification: Dimension: 133x 120x 393mm
Unidades de venda | : | Piece/Pieces |
Tipo de pacote | : | Carton |
Exemplo de imagem | : |
The file is encrypted. Please fill in the following information to continue accessing it
Implementando o sistema de filtragem adequado para proteção e purificação, você pode reduzir o tempo de inatividade da máquina e o custo geral, bem como limitar a quantidade de manutenção, reparo e uso de energia necessários. Mas você também precisa manter os filtros para obter os melhores resultados, pois filtros entupidos ou gastos podem causar uma queda significativa de pressão, tornando o compressor menos eficaz.
Como funciona um filtro de ar comprimido?
Os sistemas de ar comprimido requerem ar limpo para funcionar corretamente e fornecer ar para aplicações que não danifiquem o maquinário. Os filtros de ar que funcionam corretamente consistem em pré-filtros e filtros posteriores:
Pré-filtros: Esses filtros prendem e filtram o ar úmido e sujo que entra no secador de ar.
Depois dos filtros: esses filtros filtram o ar seco à medida que sai do secador.
Filtros de partículas capturam detritos, óleos e outros contaminantes grosseiros. O ar então entra no filtro coalescente, que se livra de impurezas finas como água ou aerossóis de óleo. Depois que o ar sai do secador, ele passa por outro filtro de partículas para garantir que o ar esteja totalmente limpo.
Recursos e benefícios
O segundo garante a carcaça do filtro de ar comprimido por quinze anos nas condições de operação recomendadas.
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Particle removal (ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Outlet oil aerosol concentration (ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Filtration performance of Particle (ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil (ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Element spanlife | 6000 hours | 6000 hours | 6000 hours | 6000 hours | 2000-3000 hours | 4000-6000 hours | 4000-6000 hours |
Filtration Type | Coalescence | Coalescence | Coalescence | Coalescence | Adsorption | Coalescence | Coalescence |
Airflow direction | From inside to outside | From outside to inside |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
HG017 | RC1/2" | 16.7 | 1.0 | 35.3 | 92 | 83 | 265 | - | - | - |
HG025 | RC3/4" | 25 | 1.5 | 53 | 92 | 83 | 265 | - | - | - |
HG030 | RC1/2" | 30 | 1.8 | 63.6 | 92 | 83 | 285 | 17.5 | 193 | 158 |
HG035 | RC3/4" | 33.3 | 2 | 70.6 | 92 | 83 | 285 | 17.5 | 193 | 158 |
HG058 | R3/4" | 46.7 | 2.8 | 98.9 | 132 | 120 | 393.5 | 24.4 | 257.6 | 195 |
HG068 | RC1" | 60 | 3.6 | 127.1 | 132 | 93.3 | 393.5 | 24.4 | 257.6 | 195 |
HG080 | RC1" | 80 | 4.8 | 169.5 | 132 | 119.6 | 502 | 24.4 | 356.2 | 300 |
HG145 | RC1" | 120 | 7.2 | 254.2 | 132 | 19.6 | 502 | 24.4 | 356.2 | 300 |
Technical requirements | Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Como escolher o filtro certo para o seu sistema de compressor de ar?
Quando você está trabalhando com compressores de ar, a purificação e a filtração do ar são uma parte crítica da manutenção. Os filtros de ar comprimido desempenham um papel importante em seu sistema de compressor de ar industrial. A escolha do filtro certo não só aumenta a eficiência de sua unidade, mas também pode reduzir os custos de energia e proteger seus funcionários de partículas e produtos químicos nocivos.
No entanto, todos os filtros de ar funcionam para o seu sistema de ar comprimido? Bem, dependendo de suas condições de trabalho , do projeto que você está concluindo e da frequência com que usa seu equipamento, você precisará fazer uma escolha precisa . Este guia irá detalhar como os filtros do compressor de ar funcionam, por que eles são importantes , que tipo de filtro do compressor de ar comprar e quando você deve substituí-lo.
①Assess the requirements of your application. Different industry require different solution. | ||||||||
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. | ||||||||
③Any specific micron of filtration performance you required? | ||||||||
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) | ||||||||
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment. | ||||||||
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.